The I/O feature that assigns I/O stipple to give PLC and input / the join that exports equipment pursues or corresponding relation is expressed, this part also can undertake in the 2nd pace. 2.
Picture of circuitry of hardware of design PLC periphery gives the electric circuit picture of systematic other part, include main circuit and the control circuit that did not enter PLC to wait. By the I/O join graph of PLC and PLC periphery electric circuit is pursued the electric principle plan that forms a system. Hereto electric circuit has decided systematic hardware. 5, of programming of Plc of 3 water chestnut 1.
Programming asks according to systematic control, use appropriate design method to design program of PLC of 3 water chestnut. The program wants to ask in order to satisfy systematic control to give priority to a line, one by one writes implementation to control function or each each child the program of the task, perfect the function that the system assigns stage by stage. Besides, the program still should include the following content normally: 1) initialization program. After electrify of PLC of 3 water chestnut, want to become the operation of a few initialization commonly, to start necessary preparation, avoid systematic happening misoperation. The main content of initialization program has: Wait to certain data division, tally undertake to clear, undertake resumptive to what certain data division requires data, undertake set or restoration to certain relay, undertake indication waiting a moment to certain and initiative condition. 2) detects, breakdown is diagnosed and show wait for a program. These courses are relatively independent, add again when programming is finished basically commonly. 3) is protected and interlink a program. Protection and chain are the indispensable part in the program, must try to consider seriously. The control logic that because be operated illegally,it can avoid and causes is confused. 2.
The basic idea that program imitate debugs program imitate is, produce the spot with convenient formal imitate actual condition, for the ambient conditions with the moving necessary creation of the program. Differ according to producing the kind of spot signal, imitate is debugged have hardware imitate law and software imitate way two kinds of forms. Law of 1) hardware imitate is to use device of a few hardware (if use another PLC or parts of an apparatus of a few inputs to wait) the signal of imitate generation spot, connect these signal the input end of PLC system with the means of hard wiring, meantime effect sex is stronger. Law of 2) software imitate is additional in PLC of 3 water chestnut write a simulator, imitate provides spot signal, its go easily simply, but sex of effectiveness for a given period of time assures not easily. Imitate debugs a process in, can use the method that section debugs, use process designing implement monitoring function. 6, hardware of Plc of 3 water chestnut carries out hardware to carry out a respect basically is to undertake controlling ark (stage) the design that waits for hardware and spot construction. Main content has: The electric equipment of the part such as ark of 1) design control and work station decorates graph and installation hookup. 2) designs a system between each part electric interrelate graph. 3) undertakes spot wiring according to construction blueprint, have detailed examination. Because programming and hardware are carried out,can undertake at the same time, because PLC of this 3 water chestnut controls systematic design,cycle can shorten greatly. 7, debugging on-line of debugging on-line of Plc of 3 water chestnut is to will pass the program that imitate debugs to undertake online all is moved further. Debugging on-line process should successive, join only from PLC of 3 water chestnut input equipment, join again output equipment, receive again on real load undertake debugging stage by stage. If do not accord with a requirement, make to hardware and program adjust. Need to modify halfway program only normally can. Debug entirely after ending, consign tries move. Move through period of time, if work,normal, program does not need to revise, answer to go to program solidify in EPROM, in case the program is missing. CNC Milling